safety
Specify how a qvm process instance responds if any component or vdev it uses isn't safety-certified
Synopsis:
safety none|warn|required
Options:
- none
- Look for the safety-certified version of each component and, if found, load it; otherwise, load the non-safety version and don't issue a warning.
- warn
- Look for the safety-certified version of each component and, if found, load it; otherwise, load the non-safety version but issue a warning.
- required
- Look for the safety-certified version of each component and, if not found, issue an error message and move the hypervisor to the global Design Safe State (DSS).
- QNX Hypervisor for Safety (QHS) — required
- QNX Hypervisor — none
Description:
Use the safety option to specify how each qvm process instance responds to the presence of uncertified (i.e., non-safety) components or vdevs.
- the filename has the -safety suffix (e.g., vdev-virtio-blk-safety.so instead of vdev-virtio-blk.so)
- the vdev has the VDEV_SAFETY bit set at compile time.
If you're building your own safety-certified vdevs,
contact the QNX support team for details on
how to proceed.
If you don't set this bit and instead try to rename a vdev to include the -safety suffix, qvm doesn't consider this to be a safety variant.
- the vdev went through safety certification
If you specify multiple safety option instances in a VM configuration, the final option instance determines how qvm responds to the presence of uncertified components (e.g., an uncertified procnto or smmuman variant).
safety warn
vdev foo
safety required
vdev moo
In a QHS VM for a QOS guest, this configuration issues a warning and permits the
qvm process instance to continue
if the foo vdev isn't a safety variant, but moves to the DSS
if the moo vdev isn't a safety variant.
The qvm process also moves to the DSS if any other required
safety component such as procnto or smmuman
isn't a safety variant.vdev foo
safety warn
vdev moo
In this case, because required is the default
safety setting for QHS, the qvm process instance
moves to the DSS if the foo vdev isn't a safety variant.
But because warn is the setting for the last
safety option, the qvm process instance issues a
warning but still runs if the moo vdev or any other required safety
component isn't a safety variant.For more information about how the QHS behaves when it encounters uncertified
components, see QHS components
in the
QNX Hypervisor for Safety: Protection Features
chapter.